1. LED lights in the passenger area provide sufficient brightness for passengers 6-seater blue brand vaccine cold chain vehicle small blue brand cold chain vehicle manufacturer Jiangling Ford Transit double row vaccine cold chain vehicle factory price Jiangling Ford Transit v362 vaccine cold chain vehicle | C Zhaolan brand vaccine cold chain vehicle can seat 6 people | Cold chain vehicles are smarter than refrigerated vehicles Vaccine cold chain car offer | Jiangling Ford Transit v362 vaccine cold chain car offer Ford v362 vaccine cold chain car offer small blue brand cold chain car manufacturer Jiangling Ford Transit double row vaccine cold chain car factory price Jiangling Ford Transit v362 vaccine cold chain vehicle | C Zhaolan brand vaccine cold chain vehicle can seat 6 people | Cold chain vehicles are smarter than refrigerated vehicles Vaccine cold chain car offer | Jiangling Ford Transit v362 vaccine cold chain car offer We have a vaccine cold chain vehicle announcement issued by the Ministry of State, which meets the data requirements of the Ministry of State! Please rest assured to buy our vaccine cold chain truck! The vaccine transport vehicle declared by our manufacturer in the national industrial information department announced the vehicle type: vaccine cold chain vehicle. Medicine refrigerated trucks are developed on the basis of ordinary refrigerated trucks. Cold chain vehicles and transportation vehicles have high requirements for technical performance and indicators, requiring full-process temperature monitoring, vehicles, temperature recording, printing, alarming, curve display and other functions.
Why say closed cooling tower is energy saving and environmental protection equipment, more and more users are using this kind of equipment to replace the original equipment (open tower), we can through data analysis and comparison, the two energy data accounting can be obvious. Energy consumption is basically two major aspects, one is water, the other is electricity. Both are energy costs that no cooling tower can escape, unless you leave the equipment on.
First of all, look at the consumption of water. Water is generally consumed in two aspects. One is the flying overflow after spraying, and the other is the evaporation consumption of water.
Let's look at the open cooling tower, the spray water of the tower is basically between two and three percent of the overflow rate, if we according to the daily operation of 10 hours, excluding holidays, 280 days of operation. According to the actual open cooling tower flow of 6000 cubic meters per hour to calculate. 6000*2%*10*280= 336,000 tons of water, and the same closed cooling tower, its spray flying overflow is very small, because after all, the spray work is carried out in the tower, almost can be controlled in a few thousandths, we calculate according to 5 thousandths, the same is 10 hours of work, 280 days a year operation, To achieve the same cooling amplitude is basically 4,500 tons per hour of closed cooling tower is enough, then the calculation results: 4,500 *0.5%*10*280= 63,000 tons, it is not difficult to see, because of the different design structure caused by the waste of spraying water resources, more than 200,000 tons of terror. The bigger the pool of the open tower, the more wasted water, because the evaporation area increases, and the closed cooling tower has no pool, so the consumption here is zero. Judging from the price of a ton of water, just such a equipment, a year to solve the capital of hundreds of thousands of enterprises.
Let's look at the comparison of electric energy, electric energy is not different, because they are all through the same power equipment to operate the equipment, the power of the two is similar, the running time is the same, basically the energy consumption is about the same.
To sum up, for the closed cooling tower energy saving accounting can be strong to open the tower out, and, today are advocating energy conservation and environmental protection, this is the general trend, so the closed cooling tower is more and more favored by the majority of users.
Closed Cooling Tower,Closed Circuit Cross Flow,Closed Loop Cooling Tower,Closed Circuit Cooler Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.arkfluid.com
Vaccine cold chain car configuration CDC vaccine delivery vehicles Ford surrounded minister _ _ ventilation slots vaccine truck factory where the phone beams
How much is the Ford V362 vaccine cold chain vehicle and where is the manufacturer? The picture below shows a single-row 6 cubic meter picture
Vaccine cold chain vehicle configuration_Ford disease control vaccine delivery vehicle four-sided ventilation slot_where is the vaccine transport vehicle manufacturer Minister Liang
2. The rear cabin LED lighting provides sufficient brightness for the staff
3. The inner layer of 304 stainless steel is a nationally recognized food grade stainless steel, which has good corrosion resistance, heat resistance, low temperature strength and mechanical properties
4. The four-sided ventilating diversion grooves ensure that the bottom of the cargo and the sides do not completely contact the car body, ensuring the air circulation of the entire car body (especially the bottom)
5. The ultraviolet disinfection lamp can effectively ensure the disinfection of the car body
6. The cold chain intelligent management system is centered on the vehicle terminal M5 , the host 3.5 -inch touch color LCD screen display, wireless temperature and humidity integration, and Bluetooth printer for intelligent monitoring
7. The temperature of the domestic refrigerator unit (top mounted) is automatically adjusted to achieve the combination of power and refrigeration. It can be operated in the cab, which is simple and convenient, and the temperature can reach -15 ℃.
8. Stainless steel door locks have the characteristics of light weight, high strength and corrosion resistance.
Our factory quickly launched a series of "big health vehicles" such as vaccination vehicles, nucleic acid sampling vehicles, medical examination vehicles, vaccine cold chain vehicles, sterilization vehicles, isolation transfer vehicles, and disinfection and epidemic prevention vehicles to help prevent and control the epidemic.
Special vaccine transport vehicle manufacturer for disease control_Ford vaccine cold chain vehicle manufacturer_v362 new vaccine cold chain vehicle manufacturer direct supply.
Vaccine cold chain vehicle configuration_Disease control vaccine delivery vehicle_Ford four-sided ventilation slot_Vaccine transport vehicle manufacturer When the disease control agency finds abnormal information such as aggregation, it should immediately organize professional and technical personnel to investigate and verify, and carry out investigation and disposal in time to ensure Effectively control emerging events.
Vaccine cold chain vehicle configuration_CDC vaccine delivery vehicle Ford four-sided ventilation slot_Vaccine transport vehicle manufacturer where is the manufacturer's phone director
Vaccine cold chain vehicle configuration_Disease control vaccine delivery vehicle_Ford four-sided ventilation slot_Vaccine transport vehicle manufacturers where almost everyone has no immunity against the new crown virus, is susceptible to the new crown virus, and most of them will be infected Diseases, and some will develop into critical illness or death. After being vaccinated, most people can gain immunity.