The specific electrical parts used in a Construction Hoist may vary depending on the manufacturer and model. It is always recommended to refer to the hoist's user manual or consult with a professional for accurate information. Construction Hoist Motor,Construction Hoist Limit Device,Construction Hoist Electric Parts,Construction Hoist Reducer,Sliding Contact Line SHEN YANG BAOQUAN BUSINESS CO., LTD , https://www.sytoplesstowercrane.com
                  HFC-227ea/FM200 Pneumatic Filling Machine
GBS-RP04-06-ES filling system (filling pump, precision pressure gauge, pressure reducing valve, high pressure electromagnetic valve, electric control part, etc.) and non-standard parts (weighing machine, vacuum pump)
2. Machine characteristics
GBS-RP04-06-ES filling equipment using the compressed air as power source, driving the HFC-227ea/FM200 filling and conveying, when the transmission weight reaches a certain value, the sensor signal is transferred to the gas electromagnetic valve, turn off the gas supply, pump stops working.
Then Connecting the nitrogen gas source, open the high-pressure nitrogen gas valve injection of nitrogen; when precision pressure gauge shows the needed nitrogen pressure then close the nitrogen valve; filling finished; It has the characteristics of small volume, light weight, simple operation, reliable performance. Especially suitable for the filling of heptafluoropropane in fire fighting industry.
            2. Main parameters of GBS-RP04-06 Model FM200 Pneumatic Charging Machine:
                  HFC-227ea/FM200 Pneumatic Filling Machine
GBS-RP04-06-ES filling system (filling pump, precision pressure gauge, pressure reducing valve, high pressure electromagnetic valve, electric control part, etc.) and non-standard parts (weighing machine, vacuum pump)
2. Machine characteristics
GBS-RP04-06-ES filling equipment using the compressed air as power source, driving the HFC-227ea/FM200 filling and conveying, when the transmission weight reaches a certain value, the sensor signal is transferred to the gas electromagnetic valve, turn off the gas supply, pump stops working.
Then Connecting the nitrogen gas source, open the high-pressure nitrogen gas valve injection of nitrogen; when precision pressure gauge shows the needed nitrogen pressure then close the nitrogen valve; filling finished; It has the characteristics of small volume, light weight, simple operation, reliable performance. Especially suitable for the filling of heptafluoropropane in fire fighting industry.
            2. Main parameters of GBS-RP04-06 Model FM200 Pneumatic Charging Machine:
1. Control panel: This is the main electrical component that allows the operator to control the movement of the hoist. It typically includes switches, buttons, and indicators for various functions such as raising, lowering, and stopping the hoist.
2. Motor: The motor is responsible for providing the power to operate the hoist. It converts electrical energy into mechanical energy to lift and lower the load.
3. Limit switches: These switches are used to set the upper and lower limits of the hoist's movement. They help prevent the hoist from overtraveling and causing damage.
4. Emergency stop button: This is a safety feature that immediately stops the hoist's operation in case of an emergency or malfunction.
5. Overload protection: This is a safety mechanism that automatically stops the hoist if it exceeds its maximum load capacity. It helps prevent accidents and equipment damage.
6. Electrical cables and wiring: These components connect the various electrical parts of the hoist, allowing for the transmission of power and control signals.
7. Circuit breakers and fuses: These protective devices are used to prevent electrical overload and short circuits. They automatically cut off the power supply in case of excessive current flow.
8. Voltage regulator: This device ensures a stable and consistent supply of electrical power to the hoist, protecting it from voltage fluctuations.
9. Sensors: Various sensors, such as proximity sensors or limit switches, are used to detect the position, speed, or presence of objects in the hoist's path. They provide feedback to the control system and help ensure safe and efficient operation.
10. Wiring connectors and terminals: These components are used to connect and secure the electrical wires in the hoist, ensuring reliable and safe connections.
Model NO.: GBS-RP04-06-ES
Control Model: Automatic Control with Electrical Scale
Applicable Gas: FM200 Gas, Hfc-227ea Gas
Pressure: High Pressure
Application: Filling FM200 Cylinder
Trademark: SHINEEAST
Transport Package: Export Standard Plywood Box
Origin: Jinan, China
HS Code: 8414809090
Model NO.: GBS-RP04-06-ES
Control Model: Automatic Control with Electrical Scale
Applicable Gas: FM200 Gas, Hfc-227ea Gas
Pressure: High Pressure
Application: Filling FM200 Cylinder
Trademark: SHINEEAST
Transport Package: Export Standard Plywood Box
Origin: Jinan, China
HS Code: 8414809090
                           SHINEEAST own manufactured
1.    Machine Composition
Product name:
FM200 Pneumatic Charging Machine
Specification:
GBS-RP04-06-ES
Core component:
Shineeast RP04-06 Booster pump
FM200 output pressure:
0-4.2Mpa
Nitrogen output pressure:
0-100 bar(adjustable)
Pressure of nitrogen gas source:
<15Mpa
Filling medium:
FM200, nitrogen gas
Filling weight:
0-500KG(can be set according to practical conditions)
                           SHINEEAST own manufactured
1.    Machine Composition
Product name:
FM200 Pneumatic Charging Machine
Specification:
GBS-RP04-06-ES
Core component:
Shineeast RP04-06 Booster pump
FM200 output pressure:
0-4.2Mpa
Nitrogen output pressure:
0-100 bar(adjustable)
Pressure of nitrogen gas source:
<15Mpa
Filling medium:
FM200, nitrogen gas
Filling weight:
0-500KG(can be set according to practical conditions)