2500 Quintuplex Plunger Pump is applicable for Fracturing, Cementing, Sand proof, acidizing etc. Compared with the same rated power pump, The pump's volume and weight are increased a lot, but its capacity increased by nearly 1.7 times, so that the work efficiency has been a qualitative leap. The pump also adopts herringbone gear reducer, its operation is stable and reliable. New spring supporting structure for the fluid end, not only improve the volumetric efficiency, but also make maintenance and repairment more convenient. 2500 Quintuplex Plunger Pump,Quintuplex Plunger Pump,Oilfield Quintuplex Plunger Pump,Oilfield Well Service Plunger Pump Henan Youlong Petroleum Engineering Technology Co.,Ltd , https://www.youlongenergy.com
“There is no need to arrange communication cables at the site, the construction cost is low, and the mobile operation and maintenance within the station can be realized...†4G wireless communication seems to have many irreplaceable advantages in the application of photovoltaic power stations. However, the ideal is very full, but the reality is very skinny.
1 Introduction
Photovoltaic power plant has large data volume, many monitoring nodes and relatively dispersed, and there are various high-voltage signal interferences in the field. Many reasons have brought great challenges to the operation stability and reliability of 4G wireless monitoring systems, especially scheduling reliability. . After a field trip to a photovoltaic power plant in northwest China, the author discovered that after the grid-connected operation of the 100MW power plant for one year, the system still reported 60,387 alarm records in one month, of which more than 30% were communication failures. There was no coincidence. The author recently visited a photovoltaic power station in Inner Mongolia. At the same time, similar phenomena were discovered. If you consider the unfavorable factors such as high initial investment cost and later professional operation and maintenance, 4G wireless communication seems to have become a gimmick in the application of photovoltaic power plants. What is the pros and cons of 4G wireless communication monitoring solutions? The author then takes you from the perspective of professional technology to reveal your true colors!
2 PV power plant monitoring system architecture
Photovoltaic system wired communication scheme and 4G wireless communication scheme system topology is shown as in Fig. 1.
Figure 1 Topological diagram of photovoltaic power plant monitoring system
In the wired solution, each power generating unit internally outputs and forms a ring network in the form of optical fibers, and uploads the data to the monitoring center through the core switch. In the 4G wireless communication scheme, a wireless base station needs to be built in the power station, and each photovoltaic unit passes through the wireless and base stations. For communication, the core network equipment in the base station then converts the wireless signal into a wired signal and uploads it to the monitoring center.
3 Reliability Analysis
4G wireless transmission rate is low, easily affected by obstacles such as hills
The optical fiber communication capacity is large, the transmission rate can reach 10000Mbps, and the communication channel bandwidth that 4G wireless scheme can adopt is maximum is only 10MHz, the theoretical communication speed is only 40Mbps, therefore, the transmission speed of 4G wireless communication is much lower than the wired communication. And the wireless network is vulnerable to the influence of structures such as buildings, trees, and other obstructions, which impedes the transmission of electromagnetic waves. Not all corners can be covered, such as hills, and only by automatically decelerating to achieve a seamless wireless connection, guarantees Connected, it will need to lose the transmission rate! For large-scale power plants, the area is relatively large, and the digital transmission terminal of the farthest square matrix is ​​far away from the base station and is easily lost during signal transmission, causing communication failure. Therefore, in large desert power station or hill power station, in order to prevent signals from being blocked and affect communication and other reasons, the wireless receiving base station is installed on the spot in the center of the collection square, and then is led to the central control room through a long distance optical fiber.
• 4G wireless solution has poor anti-electromagnetic interference and is easily affected by high voltage wires in photovoltaic power stations
The transmission signal of optical fiber communication is light instead of electricity. Not only is the loss small when the signal is transmitted, but it is not interfered by strong electromagnetic fields generated by the high-voltage wires in the plant. At the same time, the fiber ring network can automatically recover services in the event of an unexpected network failure. The network has strong survivability, the self-healing time is less than 20 ms, and the communication link is stable and reliable. The wireless system is poor in anti-electromagnetic interference and it is easy to generate adjacent-channel interference and inter-modulation interference. According to a wireless test conducted by China Mobile in a certain area of ​​Guangzhou, as a result of antenna intermodulation interference, the uplink throughput of the community is lost by 37% to 47%. The decline in throughput will cause important data to be reported inaccurately, resulting in communication links under severe circumstances. Interrupted. At the same time, the station's wireless signal is not only the "victim" of the interference, but it may also become a "pollution source", causing interference to other wireless signals around the station and even affecting aviation.
• 4G wireless solution has poor anti-electromagnetic interference and is vulnerable to bad weather
Fiber-optic communications use optical fibers as the transmission medium, buried under the ground, and are not affected by the weather. The 4G wireless signal is susceptible to thunderstorm weather. According to the British "Focus" monthly report, dampness will weaken radio waves. Under normal circumstances, the propagation speed of radio waves in rain and snow is approximately 3/4 of that in sunny weather. The penetrating power is weakened and the transmission range is reduced. On September 13, 2006, the Australian News Network reported that US researchers have indicated that thunderstorms on the earth can interfere with radio transmissions and signal transmission from communication equipment, which can easily cause temporary disruption of wireless networks and even cause damage to outdoor wireless equipment.
• Poor data security for 4G wireless solutions
The wavelength of the light wave used in optical fiber communication is very short, the frequency is very high, the transmission band is very wide, it is easy to use digital communication, digital encryption can be performed, and the optical signal is transmitted only in the optical zone, basically no "leakage" of light, no string Sound interference, high data security. The wireless signal spreads in an open space. As long as the wireless access point (AP) covers the range, the terminal can receive the wireless signal. Like the radio transmission in the anti-Japanese film, the signal is easily monitored and the data is caused. Give way. Even the most reliable encryption method can easily be attacked by hackers. With the continuous increase in the installed capacity, photovoltaic power generation as an important part of the multi-energy interconnected system, its operational safety requirements are getting higher and higher. The photovoltaic power plants monitored by 4G wireless solutions have serious potential for safety in power generation.
• 4G wireless scheme scheduling reliability is poor
The 4G wireless communication scheme has susceptibility to interference in engineering practice, slow data transmission, and even communication interruption and other issues, which directly affect the real-time and stability of power grid dispatch. The power grid companies in some regions have separately issued measures for the management of photovoltaic power plant voltage and reactive power regulation. They clearly stipulate that the communication link between the inverter inside the station—the communication cabinet—the monitoring back-end should use optical fiber communication and receive AGC/AVC scheduling. The response time of the command or output plan curve should not exceed 10 s. Moreover, the dedicated wireless frequency band needs to apply to radio regulatory agencies in various places. It is difficult and there is no corresponding standard for the use of wireless in the industry. The legitimacy of the radio frequency band has been questioned.
• Poor performance in field applications for 4G wireless solutions
When the author visited a northwest photovoltaic power station in the country, the photovoltaic power station adopted a 4G wireless communication scheme provided by a company. One year after the power station was connected to the grid, the system still reported 60,387 alarm records in a month, of which more than 30% were communication failures. As shown in Figure 3. Coincidentally, the same thing happened to the author's recent inspection of the Inner Mongolia First Power Station. Since the power station was connected to the grid in 2014, the wireless monitoring system used in the power plant has continued to be a problem, with an average of 3,000 failures reported per day, most of which are equipment. communication fail. The troubles of the wireless network fault are difficult to find. When the equipment is used for monitoring and debugging, the fault may not be repeated. If the fault is not monitored, the fault will occur again. The wireless manufacturer's technicians still have problems in on-site commissioning for a few months. It is difficult to debug and requires high professional standards. It brought huge workload and risks to the operation and maintenance of the power station in the later period, which increased the operation and maintenance costs.
4 Investment cost comparison
4.1 The initial investment in the 4G wireless scheme of the 50MW power plant is 1.23 million higher than that of the cable program
For wired communication solutions, if you consider that the power station has video data requirements and bandwidth limitations, 10 to 15 power generation units can be used to form a fiber ring network. Taking a 50MW photovoltaic power station as an example, the author assumes that each 10MW of a 50MW photovoltaic power station forms a fiber ring network. According to the system design and the topology of the monitoring system shown in Fig. 1, the power generation unit to the monitoring center is obtained under two communication methods. The main equipment configuration list and costs are shown in Table 2.
50MW Power Station Different Communication Plan Equipment Configuration List and Cost Comparison
The initial investment of the 50 MW photovoltaic power station adopting the 4G wireless communication scheme is higher than the initial investment of the optical fiber Ethernet wired communication scheme by about 1.23 million yuan, which is equivalent to an increase of 2.4 points/W initial investment.
In addition, the 4G wireless solution requires the engineering survey and design of the wireless network to be completed in the early stage. In the mid-commissioning stage, special technicians are required to perform the interference source test and debug the backbone network. The communication base station and the data transmission terminal need to be powered by an external power supply. Power selection and construction wiring costs. In the wired solution, the communication line layout can share a cable channel with the power line, which does not require additional construction wiring costs. The cost comparison in Table 2 shows that the cable solution is lower than the initial investment of the 4G wireless solution, even considering the cost of the cabling construction.
4.2 The operation and maintenance cost of the 4G wireless solution is 1.02 million yuan higher than that of the wired solution
• Comparison of labor costs. The cable technology is mature, debugging is simple, and no professional technical personnel are required for operation and maintenance in the later period. The wireless network requires professional and technical personnel with knowledge of the network to carry out network equipment operation and maintenance. The requirements for personnel quality are relatively high, which intangibly increases the manpower for the operation and maintenance of the power station. cost. The larger the scale of photovoltaic power plants, the more facilities in the network and the more complex the transmission structure, the more difficult and the scope of maintenance of network equipment will increase, and labor costs will increase further. If 50MW power station photovoltaic power station employs only one professional who understands the network, the annual salary is estimated to be 40,000 yuan higher than that of ordinary operation and maintenance personnel, and the operational cost of the 4G wireless solution within the 25-year life cycle of the photovoltaic power station will be increased by 1 million yuan over the wired solution. .
• Comparison of equipment replacement costs. For a power station, there are many wires buried in the ground, and fiber is only a small part of them. Marking is usually done on the spot to prevent damages in later construction. Therefore, the probability of fiber being cut off is extremely low. At the same time, the main equipment switches used in the cable solutions are mature products that have been applied for a long time, have low failure rates, low prices, and low equipment replacement investment costs. In addition, some devices, such as antennas, in radio remote units (RRUs) of wireless communication base stations adopt outdoor installation methods. Even if they do not consider the destruction of natural disasters such as thunder and lightning, they generally need to be replaced in 7 years or so, and have a 25-year life cycle. The power station needs to be replaced at least 3 to 4 times. If the replacement is calculated at 30,000 yuan, the investment cost of equipment in the later operation and maintenance will be 90,000 to 120,000.
Considering only the operation and maintenance labor costs and outdoor antenna replacement, a 50MW photovoltaic power station, the operation and maintenance cost of the 4G wireless solution is about 1,027,000 higher than that of the wired solution, and from Table 2 it can be seen that the power generation unit of the cable solution is in the monitoring center. The initial investment is only about 400,000 yuan. Therefore, even if some manufacturers on the market currently use the free gift method in order to promote the 4G wireless communication solution of the photovoltaic power station, it is still uneconomical from the perspective of later operation and maintenance costs.
5 Conclusion
I believe that through the technical analysis of the above professional perspective, you can see at a glance. 4G wireless monitoring solutions have many disadvantages, such as high investment costs, unstable system operation, high communication failure rate, and failure to respond to power system scheduling requirements in real time. This makes them a gimmick in photovoltaic power plant applications, providing reliability and future operation for power plants. Operation and maintenance have brought huge hidden troubles. In contrast, the cable solution not only has high reliability, but also has a low investment cost and is easy to operate and maintain in the later period. It is still the mainstream monitoring solution for the global photovoltaic industry. This is true even in Europe and the United States, where the human cost is very high.